Power Supply

As you know well, Power Supply units are essential to electronic devices. ICS selects and sells various kinds of switching power supply units, high reliability, high performance and custom design, for various applications such as medical, light source, industrial use, etc., by utilizing our original circuit design techniques with know-how accumulated as a capacitor manufacturer. We provide power supply units that meet with customers' needs by achieving energy saving, low cost, high efficiency, miniaturized and low profile performances with extensive experience in R&D.

PowerView

model Total Power Consumpion Output Name Output Voltage(V) Output Current(A)
PVP-2150 215W 5VS 5.0 2.0
5VDD 5.0 5.0
12V 12.0 4.0
24V 24.0 5.5
PVP-2340 209.1W 5V 5.1 1.0
12V 12.0 7.0
24V 24.0 5.0
PVP-2341 197.74W 5V 4.1 1.4
12V 12.0 4.0
24V 24.0 6.0
PVP-2420 320.5W 5VS 5.0 1.5
5VD 5.0 5.0
12V 12.0 4.0
24V 24.0 10.0
PVP-3000 339.1W 5VS 5.1 1.0
5VD 5.0 2.0
12V 12.0 7.0
24V 24.0 10.0
PVP-3140 392.5W 5VS 5.0 1.5
5VD 5.0 5.0
12V 12.0 4.0
24V 24.0 13.0
PVP-3680 365.2W 5.2VS 5.2 1.0
5.2VD 5.2 1.0
2.8V 2.8 1.6
3.4V 3.4 2.8
12V 12.0 3.0
6VD 6.0 0.8
33V 33.0 0.0
24V 24.0 12.5
PVP-5960 581.5W 5VS 5.0 1.0
5VD 5.0 2.5
12V 12.0 7.0
24V 24.0 20.0

PVP Series

PVP-2150

■ Features
  • Application in LCD TV 32” ( Samsung / LG )
  • Stable Output
  • Protection Circuit Built-in
  • Power Factor Correction
  • Built-in inrush current protection
  • Application products for ROHS
  • Built to meet FCC class B
  • Safety Approved : ( CB : IEC60065 )
■ Environmental
  • Operating temperature range 0 to +45 deg.C.
  • Storage temperature range -20 to +70 deg.C.
  • Circuit is coated for protection against humidity
■ Electrical Specification
1. Input Requirements
  • Input Voltage Range : AC 90V~264V
  • Input Frequency Range : 47Hz~63Hz
  • Input Current Range : < 5.0A
■ Output Requirements
Output Name Output Typical (V) Variable Voltage Range(V) Voltage Tolerance (%) Output Current(A)
Min. Max.
5VS 5 - ±5 0.1 2
5VDD 5 - ±5 1 5
12V 12 - ±5 1 4
24V 24 - ±5 0 5.5
■ Mechanical Specification
  • Dimensions : 210(W) x 130(L) x 28 (H)(mm)
  • Mounting : Module

Data Sheet Download


PVP-2340

■ Features
  • Application in LED TV 40"/46"/55"
  • Stable Output
  • Protection Circuit Built-in
  • Power Factor Correction
  • Built-in inrush current protection
  • Application products for ROHS
  • Built to meet FCC class B
  • Safety Approved ( CB : IEC60065)
■ Environmental
  • Operating temperature range 0 to +50 deg.C.
  • Storage temperature range -20 to +60 deg.C.
  • Circuit is coated for protection against humidity
■ Electrical Specification
1. Input Requirements
  • Input Voltage Range : AC 100V~240V
  • Input Frequency Range : 47Hz~63Hz
  • Input Current Range : < 4.0A
■ Output Requirements
Output Name Output Typical (V) Variable Voltage Range(V) Voltage Tolerance (%) Output Current(A)
Min. Max.
5V 5.1 - - 0.1 1.0
12V 12 - - 0.1 7.0
24V 24 - - 0 5.0
■ Mechanical Specification
  • Dimensions : 245(W) x 225(L) x 11 (H)(mm)
  • Mounting : Module

Data Sheet Download


PVP-2341

■ Features
  • Application in LED TV 40"/46"/55"
  • Stable Output
  • Protection Circuit Built-in
  • Power Factor Correction
  • Built-in inrush current protection
  • Application products for ROHS
  • Built to meet FCC class B
  • Safety Approved ( CB : IEC60065)
■ Environmental
  • Operating temperature range 0 to +50 deg.C.
  • Storage temperature range -20 to +60 deg.C.
  • Circuit is coated for protection against humidity
■ Electrical Specification
1. Input Requirements
  • Input Voltage Range : AC 100V~240V
  • Input Frequency Range : 47Hz~63Hz
  • Input Current Range : < 4.0A
■ Output Requirements
Output Name Output Typical (V) Variable Voltage Range(V) Voltage Tolerance (%) Output Current(A)
Min. Max.
5V 4.1 - - 0.1 1.4
12V 12 - - 0.1 4.0
24V 24 - - 0 6.0
■ Mechanical Specification
  • Dimensions : 245(W) x 225(L) x 11 (H)(mm)
  • Mounting : Module

Data Sheet Download


PVP-2420

■ Features
  • Application in LCD TV 40” / 42” ( Samsung / LG )
  • Stable Output
  • Protection Circuit Built-in
  • Power Factor Correction
  • Built-in inrush current protection
  • Application products for ROHS
  • Built to meet FCC class B
  • Safety Approved : ( CB : IEC60065 )
■ Environmental
  • Operating temperature range 0 to +45 deg.C.
  • Storage temperature range -20 to +70 deg.C.
  • Circuit is coated for protection against humidity
■ Electrical Specification
1. Input Requirements
  • Input Voltage Range : AC 90V~264V
  • Input Frequency Range : 47Hz~63Hz
  • Input Current Range : < 6.3A
Output Name Output Typical (V) Variable Voltage Range(V) Voltage Tolerance (%) Output Current(A)
Min. Max.
5VS 5 - ±5 0.1 1.5
5VDD 5 - ±5 1 5
12V 12 - ±5 1 4
24V 24 - ±5 0 10
■ Mechanical Specification
  • Dimensions : 251(W) x 158(L) x 35 (H)(mm)
  • Mounting : Module

Data Sheet Download


PVP-3000

■ Features
  • Application in LED TV 40"/46"/55"
  • Stable Output
  • Protection Circuit Built-in
  • Power Factor Correction
  • Built-in inrush current protection
  • Application products for ROHS
  • Built to meet FCC class B
  • Safety Approved ( CB : IEC60065)
■ Environmental
  • Operating temperature range 0 to +50 deg.C.
  • Storage temperature range -20 to +60 deg.C.
  • Circuit is coated for protection against humidity
■ Electrical Specification
1. Input Requirements
  • Input Voltage Range : AC 100V~240V
  • Input Frequency Range : 47Hz~63Hz
  • Input Current Range : < 4.0A
■ Output Requirements
Output Name Output Typical (V) Variable Voltage Range(V) Voltage Tolerance (%) Output Current(A)
Min. Max.
5VS 5.1 - - 0.1 1.0
5VD 5.0 - - 0 2.0
12V 12 - - 0.1 7.0
24V 24 - - 0 10.0
■ Mechanical Specification
  • Dimensions : 331(W) x 155(L) x 22 (H)(mm)
  • Mounting : Module

Data Sheet Download


PVP-3140

■ Features
  • Application in LCD TV 46” / 47” ( Samsung / LG )
  • Stable Output
  • Protection Circuit Built-in
  • Power Factor Correction
  • Built-in inrush current protection
  • Application products for ROHS
  • Built to meet FCC class B
  • Safety Approved : ( CB : IEC60065 )
■ Environmental
  • Operating temperature range 0 to +45 deg.C.
  • Storage temperature range -20 to +70 deg.C.
  • Circuit is coated for protection against humidity
■ Electrical Specification
1. Input Requirements
  • Input Voltage Range : AC 90V~264V
  • Input Frequency Range : 47Hz~63Hz
  • Input Current Range : < 8.0A
■ Output Requirements
Output Name Output Typical (V) Variable Voltage Range(V) Voltage Tolerance (%) Output Current(A)
Min. Max.
5VS 5 - ±5 0.1 1.5
5VDD 5 - ±5 1 5
12V 12 - ±5 1 4
24V 24 - ±5 0 13
■ Mechanical Specification
  • Dimensions : 251(W) x 158(L) x 35 (H)(mm)
  • Mounting : Module

Data Sheet Download


PVP-3680

■ Features
  • Application in LCD TV 52” ( Samsung / LG )
  • Stable Output
  • Protection Circuit Built-in
  • Power Factor Correction
  • Built-in inrush current protection
  • Application products for ROHS
  • Built to meet FCC class B
  • Safety Approved : ( CB : IEC60065 )
■ Environmental
  • Operating temperature range 0 to +45 deg.C.
  • Storage temperature range -20 to +70 deg.C.
  • Circuit is coated for protection against humidity
■ Electrical Specification
1. Input Requirements
  • Input Voltage Range : AC 90V~264V
  • Input Frequency Range : 47Hz~63Hz
  • Input Current Range : < 8.0A
■ Output Requirements
Output Name Output Typical (V) Variable Voltage Range(V) Voltage Tolerance (%) Output Current(A)
Min. Max.
5.2VS 5.2 - ±5 0.01 1
5.2VD 5.2 - ±5 0 1
2.8V 5.2 - ±5 0 1.6
3.4V 12 - ±5 0 2.8
12V 12 - ±5 0.5 3
6VD 6 - ±5 0 0.8
33V 33 - ±5 0 0.02
24V 24 - ±5 0.1 12.5
■ Mechanical Specification
  • Dimensions : 280(W) x 160(L) x 40 (H)(mm)
  • Mounting : Module

Data Sheet Download


PVP-5960

■ Features
  • Application in LED TV 84"
  • Stable Output
  • Protection Circuit Built-in
  • Power Factor Correction
  • Built-in inrush current protection
  • Application products for ROHS
  • Built to meet FCC class B
  • Safety Approved ( CB : IEC60065)
■ Environmental
  • Operating temperature range 0 to +50 deg.C.
  • Storage temperature range -20 to +60 deg.C.
  • Circuit is coated for protection against humidity
■ Electrical Specification
1. Input Requirements
  • Input Voltage Range : AC 100V~240V
  • Input Frequency Range : 47Hz~63Hz
  • Input Current Range : < 6.0A
■ Output Requirements
Output Name Output Typical (V) Variable Voltage Range(V) Voltage Tolerance (%) Output Current(A)
Min. Max.
5VS 5.0 - - 0.1 1.0
5VD 5.0 - - 0 2.5
12V 12 - - 0.1 7.0
24V 24 - - 0 20.0
■ Mechanical Specification
  • Dimensions : 310(W) x 201(L) x 30 (H)(mm)
  • Mounting : Module

Data Sheet Download